DB-1

DB-1 GC Columns from Agilent Technologies

100% dimethylpolysiloxane columns are non-polar, low-bleed, and operate under high temperature limits. They are an excellent choice for general purpose use in a wide variety of applications.

  • DB-1 - reliable, cross-linked and non-polar column with low bleed and a high temperature limit, delivering superb performance for general purpose applications
  • DB-1ht - specially processed for extended temperature limits of 400 °C with excellent peak shape and faster elution times for high boilers
  • DB-1ms - excellent general-purpose GC column and ideal for GC/MS of active analytes commonly found in drug screening and environmental analyses
  • DB-1ms Ultra Inert - provides consistent column inertness performance to ensure sensitivity, performance and integrity in trace analysis

DB-1

Buy
Features

DB-1 GC Columns

Agilent J&W DB-1 is non-polar and low-bleed, and operates under high temperature limits. It is an excellent choice for general purpose use in a wide variety of applications. Precision-engineered DB-1 is bonded, cross-linked and solvent rinsable, and is equivalent to USP phase G2.
  • 100% Dimethylpolysiloxane
  • Non-polar and low bleed with a high temperature limit
  • Wide range of applications
  • Bonded, cross-linked and solvent rinsable
  • Equivalent to USP Phase G2
  • Available with DuraGuard (GC column with a built-in guard column)

Similar Phases: SPB-1, Rtx-1, BP-1, OV-1, OV-101, 007-1(MS), SP-2100, SE-30, ZB-1, AT-1, MDN-1, ZB-1


DB-1ht GC Columns

Agilent J&W DB-1ht delivers excellent performance in a range of GC/MS applications and are manufactured to the highest levels of quality and stability. Nonpolar DB-1ht columns are specially processed for operation up to 400 °C, with optimized, polyimide-coated fused silica tubing. These bonded and cross-linked columns also deliver excellent peak shape and faster elution times for high boiling compounds and are solvent rinsable.
  • 100% Dimethylpolysiloxane
  • Non-polar
  • Specially processed for extended temperature limit of 400 °C
  • High temperature, polyimide-coated, fused silica tubing
  • Excellent peak shape and faster elution times for high boilers
  • Bonded and cross-linked
  • Solvent rinsable

Similar Phases: Rxi-1HT, Stx-1ht, ZB-1ht


DB-1ms GC Columns

Agilent J&W DB-1ms is a nonpolar, low bleed column, with excellent inertness for acids and bases and an extended upper temperature limit. Using low bleed stationary phases in DB-1ms reduces column contribution to background noise, resulting in a higher signal-to-noise ratio and better sensitivity. DB-1ms is bonded and cross-linked. In addition, reduced bleed results in improved mass-spectral purity and accurate library identification. The inertness of DB-1ms provides maximum response for active analytes commonly found in drug screening and environmental analyses.
  • 100% Dimethylpolysiloxane
  • Identical selectivity to DB-1
  • Very low bleed characteristics, ideal for GC/MS
  • Improved acid performance compared to standard 100% Dimethylpolysiloxane columns
  • Improved signal-to-noise ratio for better sensitivity and mass spectral integrity
  • Bonded and cross-linked; solvent rinsable

Similar Phases: SPB-1, Rtx-1, BP-1, OV-1, OV-101, 007-1(MS), SP-2100, SE-30, ZB-1, AT-1, MDN-1, ZB-1, ZB-1ms


DB-1ms Ultra Inert GC Columns

Agilent J&W DB-1ms Ultra Inert delivers consistent column inertness performance to ensure sensitivity, performance, and integrity. With excellent peak shapes, exceptionally low bleed and high signal-to-noise ratios, DB-1ms Ultra Inert performs effectively with even the most challenging active analytes. DB-1ms is also individually tested with Ultra Inert 1ms test probe mixture for peace of mind. An inert GC flow path further enhances performance.
  • Individually tested with Ultra Inert 1ms test probe mixture
  • Consistent column inertness performance and exceptionally low column bleed
  • High quality peak shapes for challenging active analytes
  • Excellent signal-to-noise ratios
  • Minimum compound adsorption or degradation
  • Supports 0.18 mm id column configuration for higher sample throughput

Similar Phases: SPB-1, Rtx-1, BP-1, OV-1, OV-101, 007-1(MS), SP-2100, SE-30, ZB-1, AT-1, MDN-1, ZB-1, ZB-1ms

Specifications

DB-1 Temperature Specifications

ID (mm)  0.05 – 0.10 mm  0.15 – 0.32 mm  0.45 – 0.53 mm
Length (m)  10 – 40 m  10 – 150 m  5 – 105 m
Film (µm)  0.05 – 0.40 µm  0.01 - 5.00 µm  0.15 – 5.00 µm
Temperature Limits (°C)  -60 – 325/350 °C -60 – 325/350 °C 
-60 – 300/320 °C (1.50 µm)
-60 – 280/300 °C (2.00, 3.00, 5.00 µm)
 -60 – 260/280 °C (2.55, 2.65, 3.00, 5.00 µm)
-60 – 300/320 °C  (0.50, 1.00, 1.50 µm)
-60 – 320/340 °C (0.25 µm)
-60 – 320/350 °C (1.50, 2.65 µm)
-60 – 325/350 °C (1.27, 2.65, 5.00 µm)
-60 – 340/360 °C (0.10, 0.15 µm)

 

DB-1ht Temperature Specifications

ID (mm) 0.25 – 0.32 mm 0.53 mm
Length (m) 15 – 30 m 30 m
Film (µm) 0.10 µm 0.17 µm
Temperature Limits (°C) -60 - 400 °C  -60 - 400 °C

 

DB-1ms Temperature Specifications

ID (mm) 0.10 mm 0.18  0.32 mm
Length (m) 10 – 20 m 12 – 60 m
Film (µm) 0.10 – 0.40 µm 0.10 – 0.33 µm
Temperature Limits (°C) -60 – 340/360 °C
-60 – 340/350 °C (0.33 µm)
-60 – 340/360 °C

 

DB-1ms Ultra Inert Temperature Specifications

ID (mm) 0.18 – 0.32 mm
Length (m) 15 – 60 m
Film (µm) 0.18 – 0.25 µm
Temperature Limits (°C) -60 – 340/360°C